Things about ASTM-E1233-00: Standard test method for structural performance of exterior windows, curtain walls, and doors by cyclic air pressure differential.

1.1 This test method describes the determination of the structural performance of exterior windows, curtain walls, and doors under cyclic air pressure differential, using a test chamber. This test method is applicable to all curtain wall assemblies, including, but not limited to, metal, glass, masonry, and stone components.

1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen, and not the structural performance of adjacent construction.

1.3 Procedure A shall be used for life cycle test loads.
1.4 Procedure B shall be used for wind event test loads.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use

This browser does not support PDFs. Please download the PDF to view it: Download PDF.

More To Explore

Knowledge Base

The Ultimate Guide to Double Glazing

Double glazing is also known as double glazed unit, insulated glass unit, insulating glass. It is a type of glass pane that can be used

Knowledge Base

The Ultimate Guide to Laminated Glass

What is laminated glass? Laminated glass is a safety glass that is made up of two layers of glass or more layers of glass that